Maximum voltage between any terminal
and earth ground |
600 V
|
Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
|
Display |
Digital: 6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating Temperature |
-10 °C to + 50 °C |
Storage Temperature |
-40 °C to + 60 °C |
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life |
400 hours typical, without backlight |
Accuracy Specifications: |
DC millivolts |
Range:
Resolution:
Accuracy:
|
600.0 mV
0.1 mV
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy: |
6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
± ([% of reading] + [counts]): 0.5% + 2 |
AC millivolts {1} true-rms |
Range:
Resolution:
Accuracy: |
600.0 mV
0.1 mV
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
AC volts {1} true-rms |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy:
|
6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
Range:
Resolution:
Accuracy:
|
600 Ω 1 Ω
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer |
Ohms |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy:
Range/Resolution:
Accuracy: |
600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
0.9 % + 1
40.00 MΩ / 0.01 MΩ
5 % + 2 |
Diode Test |
Range/Resolution:
Accuracy: |
2.00 V / 0.001 V
0.9% + 2 |
Capacitance |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy:
Range/Resolution:
Accuracy: |
1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
1.9% + 2 > 1000 μF
5% + 20% |
LoZ capacitance |
Range:
Accuracy: |
1 nF to 500 μF
10% + 2 typical |
AC μamps true-rms
(45 Hz to 500 Hz) |
Range/Resolution:
Range/Resolution:
Accuracy:
|
600.0 A / 0.001 A
10.00 A / 0.01 A
1.5% + 3
20 A overload for 30-seconds max
|
DC μamps |
Range/Resolution:
Range/Resolution:
Accuracy:
|
600.0 A / 0.001 A
10.00 A / 0.01 A
1.0% + 3
20 A overload for 30-seconds max |
Hz (V or A input)[2] |
Range/Resolution:
Range/Resolution:
Range/Resolution:
Range/Resolution:
Accuracy: |
99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
0.1% + 2 |
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
5) Frequency is ac coupled, 5 Hz to 30 kHz for ac voltage.
|