Accuracy Specifications: |
DC millivolts |
Range: Resolution: Accuracy:
|
600.0 mV 0.1 mV ± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/Resolution: Range/Resolution: Range/Resolution: Accuracy: |
6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V ± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range: Resolution: Accuracy:
|
600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts {1} true-rms |
Range: Resolution: Accuracy:
|
600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
AC volts {1} true-rms |
Range/Resolution: Range/Resolution: Range/Resolution: Accuracy:
|
6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
Range: Resolution: Accuracy:
|
600 Ω 1 Ω Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer |
Ohms |
Range/Resolution: Range/Resolution: Range/Resolution: Range/Resolution: Range/Resolution: Accuracy: Range/Resolution: Accuracy: |
600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ 0.9 % + 1 40.00 MΩ / 0.01 MΩ 1.5 % + 2 |
Diode Test |
Range/Resolution: Accuracy: |
2.000 V / 0.001 V 0.9% + 2 |
Capacitance |
Range/Resolution: Range/Resolution: Range/Resolution: Range/Resolution: Range/Resolution: Accuracy: Range/Resolution: Accuracy: |
1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF 1.9% + 2 > 1000 μF 5% + 20% |
LoZ capacitance |
Range: Accuracy: |
1 nF to 500 μF 10% + 2 typical |
Temperature {2} (Type-K thermocouple) |
Range/Resolution: Accuracy: Range/Resolution: Accuracy: |
-40 °C to 400 °C / 0.1 °C 1% + 10 {2} -40 °F to 752 °F / 0.2 °F 1% + 18 {2} |
AC μamps true-rms (45 Hz to 500 Hz) |
Range/Resolution: Accuracy: |
600.0 μA / 0.1 μA 1.0% + 2 |
DC μamps |
Range/Resolution: Accuracy: |
600.0 μA / 0.1 μA 1.0% + 2 |
Hz (V or A input)** |
Range/Resolution: Range/Resolution: Range/Resolution: Range/Resolution: Accuracy: |
99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz 0.1% + 2 |
Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
|