This is an Auto
Range Professional Multifunction AC/DC Clamp Meter with
3999 counts. Capable to measure DC and AC voltage,
DC and AC current, Resistance, Capacitance, Temperature
(°C), Frequency, Frequency from the clamp, Duty Cycle,
Diode and Continuity Tests.
In addition to features are Relative
Measurement Mode (Zero Function) and Over range protection.
Simply clamp around an electrical conductor to allow the
electrical current in the conductor to be measured, without
having physical contact with it, or to disconnect the wiring
through which the current is flowing.
It complies with all essential health
and safety requirements set out in European Community Directives.
It also meet internationally proven safety standards such
as IEC1010-1, IEC1010-2-032, concerning electrical measuring
instruments with double insulation overvoltage category
1000V CAT II 600V CAT III and pollution degree 2.
Special Features
- Professional Multifunction AC/DC
Clamp Meter
- Test Functions DCV, DCA, ACV, ACA,
Resistance, Continuity, Diode, Capacitance, Frequency,
Frequency from Clamp, Temperature, and Duty Cycle
- Function keys: Data hold and Auto
Zero
- International Standards: CE, IEC1010-1,
IEC1010-2-032, CAT II 1000V, CAT III 600V, EMC
- Reliable and accurate measurements
- Φ40mm maximum conductor
diameter
- Ergonomic grip with bigger jaw opening
and larger conductor size
- Bigger LCD screen
- Overload Protection
- Impedance in circuit is below 30Ω
with buzzer alarm
- Auto power off and low battery indication
- Automatic Ranging
- Safety Guard and secured jacks
- Double insulated
- Design in accordance with Electromagnetic
Compatibility (89/336/EEC) & Low Voltage (73/23/EEC
as amended by CE Marking (93/68/EEC)
- Includes heavy-duty test leads and
batteries
- Accuracy:
±% of reading ±number of least significant
digits at 18~28 °C, with relative humidity up to
75%. All specifications assume less than 1 year since
calibration. Temperature coefficient: 0.1 x specified
accuracy / °C
- General Specifications:
- Maximum Voltage: 1000 V DC or
700 V AC RMS
- Altitude: < 2000m
- Display: LCD 3999 counts Update
2 ~ 3 per second
- Ranging Method: Auto Range Mode
- Polarity Indication: "-"
display for negative polarity
- Over Range Indication: LCD will
display "OL"
- Low Battery: icon will appears
on LCD
- Jaw Capability: 40mm, Max conductor
size
- Power: 3 x 1.5V AAA Batteries
- Operating Temperature: 5~35°C
- Storage Temperature: -10~50°C
- Dimension: approx. 225(L) x 86(W)
x 32(D) mm (8.86' x 3.39' x 1.26' inch)
- Weight: approx. 330g
- Electrical Specifications:
- DC Voltage
Range
|
Resolution
|
Accuracy
|
400 mV
|
0.1mV
|
±(0.8 % of reading + 5
digits)
|
4V
|
1mV
|
40V
|
10V
|
400V
|
0.1V
|
1000V
|
1V
|
±(1.0 %
of reading + 5 digits)
|
- Input Impedance : 10MΩ
(ohm)
- Overload Protection: 1000 V DC or 700 V AC RMS
- AC Voltage
Range
|
Resolution
|
Accuracy
|
4V / 50Hz
|
1mV
|
±(1.2
% of reading + 5 digits)
|
40V / 50Hz
|
10mV |
400V
/ 50Hz |
0.1V |
700V
/ 50Hz |
1V |
±(1.5
% of reading + 5 digits)
|
- Input Impedance : 10MΩ
(ohm)
- Frequency Range: 40~400Hz
- Overload Protection: 1000 V DC or 700 V AC RMS
- DC Current
Range
|
Resolution
|
Accuracy
|
400A
|
0.1A
|
±(3.0
% of reading + 5 digits)
|
1000A
|
1A |
- Overload Protection: 120
% ranges for 60 seconds max.
- AC Current
Range
|
Resolution
|
Accuracy
|
400A
|
0.1A
|
±(3.0
% of reading + 5 digits)
|
1000A
|
1A |
- Overload Protection: 120
% ranges for 60 seconds max.
- Frequency Range: 50~60Hz
- Resistance
Range
|
Resolution
|
Accuracy
|
400Ω
|
0.1Ω
|
±(1.0
% of reading + 5 digits)
|
4kΩ
|
1Ω |
40kΩ |
10Ω |
400kΩ |
0.1kΩ |
4MΩ |
1kΩ |
40MΩ |
10kΩ |
±(2.0
% of reading + 6 digits)
|
- Overload Protection: 250V
DC or RMS, AC for all ranges
- Capacitance
Range
|
Resolution
|
Accuracy
|
4nF
|
1pF
|
±(4.0
% of reading + 10 digits)
|
40 nF
|
10pF |
400
nF |
0.1nF |
4
µF |
1nF |
40
µF |
10nF |
Not Specified
|
- Overload Protection: 250
V DC or rms, AC for all ranges
- Frequency Measurement
Range
|
Resolution
|
Accuracy
|
40 Hz
|
0.01 Hz
|
±(0.1
% of reading + 1 digits)
|
400 Hz
|
0.1
Hz |
4
kHz |
1
Hz |
40
kHz |
10
Hz |
100
kHz |
0.1
kHz |
- Measurement Range: 1 V to
10 V RMS. 10~100kHz
- Frequency Measurement
for Clamp
Range
|
Resolution
|
Accuracy
|
40 Hz
|
0.01 Hz
|
±(0.1
% of reading + 1 digits)
|
400 Hz
|
0.1
Hz |
- Measurement Range: 40~400Hz
/ > 20A
- Temperature
Range
|
Resolution
|
Accuracy
|
-40~0°C
|
1°C
|
±(1.0
% of reading + 6°C)
|
1~400°C
|
±(1.0
% of reading + 3°C)
|
401~750°C
|
±(1.0
% of reading + 5°C)
|
- Audible Continuity and
Diode Test
Range
|
Description
|
Audible
Continuity
|
If continuity
exists (about less
than 30Ω), built-in buzzer will sound
|
Diode
|
Show the approx.
Forward Voltage
of the diode |
- Duty Cycle: 0.1~99.9 %
Standard Set Includes
- 3 x 1.5V AAA Battery (FREE)
- 1 x "K" type thermocouple
- 1 x Test Leads
- 1 x Protective Zippered Carrying Pouch
- Instruction Manual
- Standard packaging box
|