A digital Multimeter that has PC Connection
capability with both auto and manual range options. Autorange
mode selects the best range for the input detected and allows
you to set testing point without resetting the range. While
manual range lets you select whatever range you want as
well as it allows you to lock the meter in a specific range.
It is also capable for relative measurement and has multiple
measuring capacity such as DC & AC Current and Voltage,
Resistance, Capacitance, Frequency, Temperature (°C),
Diode and Continuity Test. Measured data can be recorded,
analyzed and processed in a computer. In addition, this multimeter supports Windows XP Home, Professional, Vista 32&64bit, and Windows 7.
Features like Data Hold, Over range protection,
Backlight LCD display, low battery indication and Auto Power
Off have been added to this meter's functionality making
it ideal tool for schools, laboratories, industries and
even home applications. Moreover, this multimeter has been
granted an iF product design award in Hannover for its cutting-edge
design quality and outstanding functionality.
Special Features
- Performs Diode test, Temperature Measurement,
Frequency and Duty Cycle, Relative Measurement
- Auto and Manual Range
- 6000 counts full feature with PC-Link
software interface (USB)
- Large LCD display with LED backlight
- Data hold function, Minimum and Maximum
value
- Auto power off and low power indication
- Over range indicator
- Conforms with IEC1010-1, CAT.II 1000
V, CAT. III 600 V
- Fuse and diode protected circuit
- Electronic protection system with
double insulation
- Supports Windows XP Home, Professional, Vista 32&64bit, and Windows 7
- Convenient fuse and battery change
design
Electrical Specifications:
Circumstance
Temperature: 18 ~ 28°C (64.4 ~ 82.4°F)
Relative Humidity: 0 ~ 75%.
DC Voltage
Range
|
Resolution
|
Accuracy
|
600 mV |
0.1 mV |
±(0.5%
of reading + 8 digits) |
6 V |
1 mV |
±(0.8%
of reading + 5 digits) |
60 V |
10 mV |
600 V |
100 mV |
1000 V |
1 V |
±(1.0% of reading
+ 10 digits) |
Input
Impedance: > 10 MΩ
Common Mode Rejection Ratio: DC voltage: > 100 dB at
DC 50 or 60 Hz
Normal Mode Rejection Radio: DC voltage: > 45 dB at
50 Hz or 60 Hz
AC Voltage
Range
|
Resolution
|
Accuracy
|
600 mV |
0.1 mV |
±(3.0%
of reading + 3 digits) manual range only |
6 V |
1 mV |
±(1.0%
of reading + 3 digits) |
60 V |
10 mV |
600 V |
100 mV |
700 V |
1 V |
±(1.5%
of reading + 3 digits) |
Frequency
Range for AC Voltage: 40 to 400 Hz
Response for AC Voltage: Average, calibrated in rms of
sine wave.
Overload Protection: 1000 V DC or 700 V AC rms
Input Impedance (Nominal): AC voltage: > 10 MΩ
Common Mode Rejection Ratio: AC voltage: > 60 dB at
DC 50 or 60 Hz
Normal Mode Rejection Ratio: DC voltage: > 45 dB at
50 or 60 Hz
DC
Current
Range
|
Resolution
|
Accuracy
|
600 µA |
0.1 µA |
±(1.5% of reading + 3 digits)
|
6000 µA |
1 µA |
60 mA |
0.01 mA |
±(1.8%
of reading + 5 digits) |
600 mA |
0.1 mA |
6 mA |
1 mA |
±(2.0%
of reading + 5 digits) |
10
mA |
10
mA |
AC
Current
Range
|
Resolution
|
Accuracy
|
600 µA |
0.1 µA |
±(1.8% of reading + 5 digits)
|
6000 µA |
1 µA |
60 mA |
0.01 mA |
±(2.0%
of reading + 8 digits) |
600 mA |
0.1 mA |
6 mA |
1 mA |
±(3.0%
of reading + 8 digits) |
10
mA |
10
mA |
Frequency
Range for AC Current: 40 to 400Hz
Response for AC Current: Average, calibrated in rms of
sine wave
Overload Protection: F 10A / 600V fuse for 10A range.
F 750mA / 600V fuse for µA and mA ranges
Maximum Input Current: 600mA DC or 600mA AC rms for µA
and mA ranges, 10A DC or 10A AC rms for 10A ranges
For measurements > 6A, 4 minutes maximum ON to measure
10 minutes OFF and above 10A unspecified
Frequency (10
Hz ~ 1 MHz)
Range
|
Resolution
|
Accuracy
|
99.99 Hz |
0.01 Hz |
±(0.1%
of reading + 3 digits) |
999.9 Hz |
0.1 Hz |
9.999 kHz |
0.001 kHz |
99.99 kHz |
0.01 kHz |
999.99 kHz |
0.1 kHz |
Overload
Protection: 250V DC or 250V AC rms
Resistance
Range
|
Resolution
|
Accuracy
|
600.0 Ω |
0.1 Ω |
±(0.5%
of reading + 3 digits) |
6.000 kΩ |
1 Ω |
±(0.5% of reading + 2 digits)
|
60.00 kΩ |
10 Ω |
600.00 kΩ |
100 Ω |
6.0 MΩ |
1 kΩ |
60.00
MΩ |
10
kΩ | ±(1.5%
of reading + 3 digits) |
Overload
Protection: 250V DC or 250V rms AC
Diode
Test
Range
|
Resolution
|
Accuracy
|
1
V |
0.001 V |
1.0% uncertainty |
Forward
DC current approximate 1mA
Reversed DC Voltage approximate 1.5V
Overload protection: 250V DC or 250V rms AC
Continuity
Check
Range
|
Resolution
|
Test Condition
|
600 Ω |
0.1 Ω |
open circuit voltage: approx 0.5V |
Description:
Continuity beep =50Ω
Overload protection: 250V DC or 250V rms AC
Temperature
Range
|
Resolution
|
Accuracy
|
-55 ~ 0°C |
0.1°C |
±
(5.0% of reading + 4°C) |
1 ~ 400°C |
±
(2.0% of reading + 3°C) |
401 ~ 1000°C |
1°C |
±
(2.0% of reading) |
Note:
The specifications of temperature do not include the thermocouple
errors
Overload Protection: 250V DC or 250V rms AC
Capacitance
Range
|
Resolution
|
Accuracy
|
60 nF |
10 pF |
±(3.0%
of reading + 20 digits) |
600 nF |
100
pF |
±(3.0%
of reading + 10 digits) |
6 µF |
1 nF |
60
µF |
10
nF |
300
µF |
100
nF |
±(5.0%
of reading + 10 digits) |
Overload
Protection: 250 V DC or rms AC
General Specifications:
-
Display:
3 5/6 digits LCD display. Automatic Indication of functions
and symbols
-
Auto
and manual range
-
Environmental
conditions: 1000V CAT.II and 600V CAT. III
-
Pollution
degree: 2
-
Maximum
Voltage between Terminals and Earth Ground: 700V AC
rms or 1000V DC
-
Polarity
indication: "-" indicates negative polarity
-
Sample
Rate: 3 times/second for digital data
-
Fuse
Protection: µA and mA: F 750mA / 250V Ø5x20
******************************
*A: F 10A/250V Ø6.35x31.8
-
Over
range indication: Display '0L'
-
Low
battery indication
-
Temperature
Coefficient: 0.1 x (specified accuracy) / °C (<18°C
or > 28°C)
-
Operating
Altitude: < 2000 m (7000 feet)
-
Operating
Temperature: 0 ~ 40°C (32 ~ 104°F) (<80%
RH, <10°C non-condensing)
-
Storage
Temperature: -10 ~ 60°C (14 ~ 140°F) (<70%
RH, battery removed)
-
Power
Supply: 9V PP3 Battery (included)
-
Dimension:
approx. 180 (L) x 85 (W) x 40 (H) mm (7.01' x 3.35'
x 1.57' inch)
-
Weight:
approx. 310g (batteries included)
One Set Includes
- 1 x Multimeter with USB connection
- 2 x Test Leads (1 set)
- 2 x Alligator Clips (1 set)
- 1 x K-Type Thermocouple
- 1 x USB adapter with cable
- 1 x PC-Link Software CD
- 1 x 9 V PP3 Battery
- 1 x Instruction Manual
- Standard Factory Package
|