The Professional Bench Top Multimeter
is a unique multi-functional device that has 4 7/8
digits Dual Display with 80,000 counts and Analog
Bar Graph with 23 segments. This precision LCR
meter is a cost-effective solution for component and material
measurement.
Measure speed is about 3 per second and
with more than 50 measuring functions including DC/AC
Voltage, DC/AC Currents, Resistance (Ω), Capacitance, Frequency
(Hz), Rotational Speed, Square Waveform, Temperature (°C/°F),
Duty Cycle, Diode and Continuity Check.
Moreover, you can connect it to your
computer through RS-232 Cable. The meter can provide
functions including analog bar and unit symbol display,
data holding, relative value measuring and maximal/minimal
value measuring.
This multimeter is most suitable for use
on production lines, laboratories, factories, radio-technology,
R & D, maintenance and repairing work.
Special Features:
- Large LCD, High contrast and Wide visual
angle LCD display with backlight
- Dual Display:
- Main Display: 80000
- Secondary Display: 80000
- Analog Bar Graph: 23 segments
- More than 50 measuring functions including DC/AC Voltage,
DC/AC Currents, Resistance (Ω), Capacitance, Frequency
(Hz), Temperature (°C/°F), Duty Cycle, Diode and
Continuity Check
- Single Analyzed:
- (AC+DC) measuring synchronous
- (AC+Hz) measuring synchronous
- (DC+dBm) measuring synchronous
- (dBm+Hz) measuring synchronous
- (Hz+Duty) measuring synchronous
- (°C+°F) displaying synchronous
- Frequency measurement: 0.5Hz to 1000.000000MHz
- Basic DC Accuracy: 0.05 %
- mV Impedance: >1000MΩ
- 16 Frequency points, 1% to 99% duty selectable square
wave output
- Analyzing component of current or voltage signal
- Resistance Measuring: 0.1Ω to 80MΩ, 10MΩ to 8000MΩ
- Capacitance Measuring:10nF to 100µF
- Temperature Measuring: -50°C to 1372°C, -58°F
to 2502°F
- dBm 20 types of reference impedance
- Auto data hold/ peak hold
- Auto data refurbish, positive, negative peak data auto
hold
- Relative measurement
- Relative measuring: REL, Relative percent: REL%
- 36 hours dynamic recording: MAX/MIN/AVG/MAX-MIN
- Communication: isolated optical RS232
- Measure speed is about 3 per second
- Timer for measurement
- Backlight display
- Safety/Compliance: IEC 61010 CAT II 1000V; CAT III 600V
- Auto power off
- 0.1 ~ 99.9% pulse duty cycle measuring
- Set upper and lower limit area measuring
- Photoelectricity insulation RS-232 computer interface
- Timing measuring function
- AC measuring adopt High accuracy RMS, Widely measuring
and AC+DC function, can measure the accuracy virtual value
of AC by any wave
Specifications
- Maximum voltage between any terminal
and earth ground: 1000V RMS
- Continuity Beeper: 3kHz Approx.
- Display: Double Digital: 80000
- Bar Graph: 23 segments, update 40 time/sec
- Operating Temperature: 0°C to +50°C; Storage
Temperature: -20°C to +60°C
- Operating Altitude: under 2000m; Storage Altitude: under
10,000m
- Relative Humidity: ≤75% at 0°C to +40°C
- Battery Type: 9V DC Adapter
- Electromagnetic Compatibility: in a RF field or 1 V/m
on all ranges and function except Capacitance
- Total Accuracy: specified +5% of range Capacitance not
specified in RF fields performance above 1 V/m is not
specified
- PC Interface: RS-232
- AC Power: 110 ~ 220 V (US / EU / AU / UK Power adapter
plug)
- Size: approx. 242 x 212 x 98 mm
- Weight: approx. 1388g (accessories not included)
Technical Specifications:
Accuracy is ±(percentage of reading
+ number of digits) at 18 ~ 28°C, 0-75% R.H.
DC Voltage
Range
|
Resolution
|
Accuracy
|
80mV
|
1μV
|
±(0.3%
rdg + 10)
|
800mV
|
10μV
|
±(0.05%
rdg + 5)
|
8V
|
0.1mV
|
80V
|
1mV
|
800V
|
10mV
|
1000V
|
0.1V
|
±(0.08%
rdg + 10)
|
AC Voltage
Range
|
Resolution
|
Accuracy
|
<75%
Range: 50Hz~20kHz
|
<75%
Range: 20Hz~50kHz
|
>75%
Range: 50Hz~20kHz
|
80mV
|
1
μA
|
±(0.8%+50)
|
±(6.0%
rdg + 50)
|
±(8.0%
+ 50)
|
800mV
|
10
μA
|
±(5.0%
rdg + 50)
|
8V
|
0.1mA
|
80V
|
1mV
|
|
750V
|
10mV
|
50Hz
~ 1kHz: <90% Range (0.8% rdg + 50) &
>90% Range: ±(5.0% rdg + 50)
|
Input
impedance: 8mV ~ 800mV >1000MΩ, 8 ~1000V: 10MΩ
DCA
Range
|
Resolution
|
Accuracy
|
Notes
|
80mA
|
1μA
|
±(0.2%rdg
+ 10)
|
Fuses:F
750mA/250V F 13A/250V Voltage drop: ≤800mV
Max. Input Current: 20A (up to 15 seconds)
|
800mA
|
10μA
|
8A
|
0.1mA
|
±(0.5%rdg
+ 10)
|
20A
|
1mA
|
ACA
Range
|
Resolution
|
Accuracy
|
Notes
|
80mA
|
1μA
|
50Hz
~ 5kHz
±(0.8%rdg + 20)
|
Fuses:F
750mA/250V F 13A/250V Voltage drop: ≤800mV
Max. Input Current: 20A (up to 15 seconds)
|
800mA
|
10μA
|
8A
|
0.1mA
|
50Hz
~ 500Hz
±(1.0%rdg + 20)
|
20A
|
1mA
|
dBm (Power Ration in decibels)
Range
|
Resolution
|
Accuracy
|
-80.00dBm
~ +80.00dBm
|
0.01
dBm
|
±1.0%
reading
|
Resistance
(Ω)
Range
|
Resolution
|
Accuracy
|
800Ω
|
0.01Ω
|
±(0.3%
rdg + 10)
|
8kΩ
|
0.1Ω
|
±(0.3%
rdg + 5)
|
80kΩ
|
1Ω
|
800kΩ
|
10Ω
|
8MΩ
|
100Ω
|
80MΩ
|
1kΩ
|
0
~ 40MΩ: ±(2.5% rdg + 10)
40 ~ 80 MΩ: ±(3.5% rdg + 10)
|
Frequency (Hz)
Range
|
Resolution
|
Accuracy
|
Note
|
999.99Hz
|
0.01Hz
|
±(0.05%
rdg+ 5)
|
Overload
Protection:
250V RMS
Sensitivity: 0.7V RMS
|
9.9999kHz
|
0.1Hz
|
99.999Hz
|
1Hz
|
999.99Hz
|
10Hz
|
8.0000MHz
|
100Hz
|
10.0MHz
|
1kHz
|
±(0.1%
rdg+ 5)
|
Plus
Adapter
|
100.0MHz
|
10kHz
|
1000.0MHz
|
100kHz
|
Capacitance
Range
|
Resolution
|
Accuracy
|
1nF
|
1pF
|
±(5.0%
rdg+ 50)
|
10nF
|
10pF
|
±(2.5%
rdg+ 50)
|
100nF
|
100pF
|
1
μF
|
1nF
|
10μF
|
10nF
|
100μF
|
100nF
|
Overload
Protection: 250 V RMS
Diode
Range
|
Resolution
|
Accuracy
|
3.0000
V
|
0.0001
V
|
±(3.0%
rdg+ 5)
|
Square Wave Output
Square
Wave Output
|
Description
|
Voltage
Amplitude
|
Approx.
3V
|
Frequency
|
0.5
~ 5000 Hz
|
Duty
Cycle
|
1
~ 99%
|
Temperature
Range
|
Resolution
|
Accuracy
|
-50
~ 1300 °C
|
0.1
°C
|
±
(1.5% rdg+ 10)
|
-58
~ 2372 °F
|
0.1
°F
|
Note:
Type K Thermocouple
Set Includes
- 1 x Digital Bench Top Multimeter
- 1 x Pair of Test Leads
- 1 x Type K Thermocouple
- 1 x RS-232 Software CD
- 1 x 9-pin Cable Adapter
- 1 x AC Power Cord (available in US / EU / AU / UK Power
Plug)
- Instruction Manual