Digital Bench Top Multimeter
with RS-232 Software CD & Cable

******



   
     

The Professional Bench Top Multimeter is a unique multi-functional device that has 4 7/8 digits Dual Display with 80,000 counts and Analog Bar Graph with 23 segments. This precision LCR meter is a cost-effective solution for component and material measurement.

Measure speed is about 3 per second and with more than 50 measuring functions including DC/AC Voltage, DC/AC Currents, Resistance (Ω), Capacitance, Frequency (Hz), Rotational Speed, Square Waveform, Temperature (°C/°F), Duty Cycle, Diode and Continuity Check.

Moreover, you can connect it to your computer through RS-232 Cable. The meter can provide functions including analog bar and unit symbol display, data holding, relative value measuring and maximal/minimal value measuring.

This multimeter is most suitable for use on production lines, laboratories, factories, radio-technology, R & D, maintenance and repairing work.

 

Special Features:

  • Large LCD, High contrast and Wide visual angle LCD display with backlight
  • Dual Display:
    • Main Display: 80000
    • Secondary Display: 80000
    • Analog Bar Graph: 23 segments
  • More than 50 measuring functions including DC/AC Voltage, DC/AC Currents, Resistance (Ω), Capacitance, Frequency (Hz), Temperature (°C/°F), Duty Cycle, Diode and Continuity Check
  • Single Analyzed:
    • (AC+DC) measuring synchronous
    • (AC+Hz) measuring synchronous
    • (DC+dBm) measuring synchronous
    • (dBm+Hz) measuring synchronous
    • (Hz+Duty) measuring synchronous
    • (°C+°F) displaying synchronous
  • Frequency measurement: 0.5Hz to 1000.000000MHz
  • Basic DC Accuracy: 0.05 %
  • mV Impedance: >1000MΩ
  • 16 Frequency points, 1% to 99% duty selectable square wave output
  • Analyzing component of current or voltage signal
  • Resistance Measuring: 0.1Ω to 80MΩ, 10MΩ to 8000MΩ
  • Capacitance Measuring:10nF to 100µF
  • Temperature Measuring: -50°C to 1372°C, -58°F to 2502°F
  • dBm 20 types of reference impedance
  • Auto data hold/ peak hold
  • Auto data refurbish, positive, negative peak data auto hold
  • Relative measurement
  • Relative measuring: REL, Relative percent: REL%
  • 36 hours dynamic recording: MAX/MIN/AVG/MAX-MIN
  • Communication: isolated optical RS232
  • Measure speed is about 3 per second
  • Timer for measurement
  • Backlight display
  • Safety/Compliance: IEC 61010 CAT II 1000V; CAT III 600V
  • Auto power off
  • 0.1 ~ 99.9% pulse duty cycle measuring
  • Set upper and lower limit area measuring
  • Photoelectricity insulation RS-232 computer interface
  • Timing measuring function
  • AC measuring adopt High accuracy RMS, Widely measuring and AC+DC function, can measure the accuracy virtual value of AC by any wave

Specifications

  • Maximum voltage between any terminal and earth ground: 1000V RMS
  • Continuity Beeper: 3kHz Approx.
  • Display: Double Digital: 80000
  • Bar Graph: 23 segments, update 40 time/sec
  • Operating Temperature: 0°C to +50°C; Storage Temperature: -20°C to +60°C
  • Operating Altitude: under 2000m; Storage Altitude: under 10,000m
  • Relative Humidity: ≤75% at 0°C to +40°C
  • Battery Type: 9V DC Adapter
  • Electromagnetic Compatibility: in a RF field or 1 V/m on all ranges and function except Capacitance
  • Total Accuracy: specified +5% of range Capacitance not specified in RF fields performance above 1 V/m is not specified
  • PC Interface: RS-232
  • AC Power: 110 ~ 220 V (US / EU / AU / UK Power adapter plug)
  • Size: approx. 242 x 212 x 98 mm
  • Weight: approx. 1388g (accessories not included)

 

    Technical Specifications:

    Accuracy is ±(percentage of reading + number of digits) at 18 ~ 28°C, 0-75% R.H.


    DC Voltage
    Range
    Resolution
    Accuracy
    80mV
    1μV
    ±(0.3% rdg + 10)
    800mV
    10μV
    ±(0.05% rdg + 5)
    8V
    0.1mV
    80V
    1mV
    800V
    10mV
    1000V
    0.1V
    ±(0.08% rdg + 10)

    AC Voltage
    Range
    Resolution
    Accuracy
    <75% Range: 50Hz~20kHz
    <75% Range: 20Hz~50kHz
    >75% Range: 50Hz~20kHz
    80mV
    1 μA
    ±(0.8%+50)
    ±(6.0% rdg + 50)
    ±(8.0% + 50)
    800mV
    10 μA
    ±(5.0% rdg + 50)
    8V
    0.1mA
    80V
    1mV
    750V
    10mV
    50Hz ~ 1kHz: <90% Range (0.8% rdg + 50) &
    >90% Range: ±(5.0% rdg + 50)
    Input impedance: 8mV ~ 800mV >1000MΩ, 8 ~1000V: 10MΩ

    DCA
    Range
    Resolution
    Accuracy
    Notes
    80mA
    1μA
    ±(0.2%rdg + 10)
    Fuses:F 750mA/250V F 13A/250V Voltage drop: ≤800mV
    Max. Input Current: 20A (up to 15 seconds)
    800mA
    10μA
    8A
    0.1mA
    ±(0.5%rdg + 10)
    20A
    1mA

    ACA
    Range
    Resolution
    Accuracy
    Notes
    80mA
    1μA

    50Hz ~ 5kHz
    ±(0.8%rdg + 20)

    Fuses:F 750mA/250V F 13A/250V Voltage drop: ≤800mV
    Max. Input Current: 20A (up to 15 seconds)
    800mA
    10μA
    8A
    0.1mA
    50Hz ~ 500Hz
    ±(1.0%rdg + 20)
    20A
    1mA

    dBm (Power Ration in decibels)
    Range
    Resolution
    Accuracy
    -80.00dBm ~ +80.00dBm
    0.01 dBm
    ±1.0% reading

    Resistance (Ω)
    Range
    Resolution
    Accuracy
    800Ω
    0.01Ω
    ±(0.3% rdg + 10)
    8kΩ
    0.1Ω
    ±(0.3% rdg + 5)
    80kΩ
    800kΩ
    10Ω
    8MΩ
    100Ω
    80MΩ
    1kΩ
    0 ~ 40MΩ: ±(2.5% rdg + 10)
    40 ~ 80 MΩ: ±(3.5% rdg + 10)

    Frequency (Hz)
    Range
    Resolution
    Accuracy
    Note
    999.99Hz
    0.01Hz
    ±(0.05% rdg+ 5)

    Overload Protection:
    250V RMS
    Sensitivity: 0.7V RMS

    9.9999kHz
    0.1Hz
    99.999Hz
    1Hz
    999.99Hz
    10Hz
    8.0000MHz
    100Hz
    10.0MHz
    1kHz
    ±(0.1% rdg+ 5)
    Plus Adapter
    100.0MHz
    10kHz
    1000.0MHz
    100kHz

    Capacitance
    Range
    Resolution
    Accuracy
    1nF
    1pF
    ±(5.0% rdg+ 50)
    10nF
    10pF
    ±(2.5% rdg+ 50)
    100nF
    100pF
    1 μF
    1nF
    10μF
    10nF
    100μF
    100nF
    Overload Protection: 250 V RMS

    Diode
    Range
    Resolution
    Accuracy
    3.0000 V
    0.0001 V
    ±(3.0% rdg+ 5)

    Square Wave Output
    Square Wave Output
    Description
    Voltage Amplitude
    Approx. 3V
    Frequency
    0.5 ~ 5000 Hz
    Duty Cycle
    1 ~ 99%

    Temperature
    Range
    Resolution
    Accuracy
    -50 ~ 1300 °C
    0.1 °C
    ± (1.5% rdg+ 10)
    -58 ~ 2372 °F
    0.1 °F
    Note: Type K Thermocouple


Set Includes

  • 1 x Digital Bench Top Multimeter
  • 1 x Pair of Test Leads
  • 1 x Type K Thermocouple
  • 1 x RS-232 Software CD
  • 1 x 9-pin Cable Adapter
  • 1 x AC Power Cord (available in US / EU / AU / UK Power Plug)
  • Instruction Manual
  • Standard Packaging Box



 


 



 




Copyright © 2008. All rights reserved. Discount Instrument
*

 

Return
Items must be returned within 30 days .
Refund will be given as Money back or exchange/replacement.
Refund policy details:
We are happy to accept returns provided that the merchandise received is an incorrect item, defective or broken. We'll notify you via e-mail of your returned postage refund once we've received returned item.
Shipping

Destination: Hong Kong

CarrierMethodShipping CostPer additional Item
STANDARDStandard$0.00$0.00

Destination: Worldwide

CarrierMethodShipping CostPer additional Item
STANDARDStandard$0.00$0.00
Payment Method

Type

Instructions to Buyer

Paypalnull
Insurance
Not Offered (Domestic)
 
Ecommerce Software Powered by Vendio | Privacy Policy